Application

LABORATORY APPLICATIONS

 

Troubleshooting manufacturing process needs more comprehensive analysis of the wafers in different process steps. Often these tests are out of scope of in-line and offline process control tools. For this purpose Semilab can offer state-of-the art laboratory tools with multiple capabilities.

These advanced metrology tools can be effectively used in the research and development field to introduce new methods and techniques for high efficiency solar cell production.

Semilab is open for cooperation with customers to improve the tool performance and introduce new applications to cover future metrology needs.

The measurement tools were designed to achieve good tool performance, user-friendly operation and low cost of ownership.

The applications include the following:  

  • Wafer contamination characterization
  • Analytical contamination detection in wafers
  • Measurement of electrical parameters in different manufacturing stages
  • Optical characterization of deposited layer parameters
  • Electrical characterization of deposited dielectric layer parameters
  • Measuring surface passivation efficiency and homogeneity
  • Testing accelerated light-induced degradation (LID) and potential-induced degradation (PID) of solar cells

Technology

DEEP LEVEL TRANSIENT SPECTROSCOPY - PV

 

Deep Level Transient Spectroscopy (DLTS) is a powerful technology for the detection and identification of electrically active defects (known as traps) in semiconductors, due to contamination or crystal defects. It is an extremely versatile method for determining all parameters associated with deep traps including energy level, capture cross section and concentration distribution. It permits identification of the impurities and is capable of detecting contamination concentrations below 5*107 atoms/cm3.

DLTS is a destructive technique, as it requires forming either a Schottky diode or a p-n junction with a small sample, usually cut from a complete wafer.

Semilab’s DLTS system is composed either of the DLS-83D, DLS-1000 or DLS-1100 and one of the four cryostats Semilab offers.

Majority carrier traps are observed by the application of a reverse bias pulse, while minority carrier traps can be observed by the application of a forward bias pulse. 

The technique works by observing the capacitance transient associated with the change in depletion region width as the diode returns to equilibrium from an initial non-equilibrium state.  

Capacitance transients generated by changing of the Voltage:

Because the emission process is very fast, the capacitance transient is small and noisy. In order to slow down the emission process, different kind of cryostats can be used for cooling the sample (usually in the range from 30 K to room temperature 300 K or above). The result of the cooling is a longer transient. By using a lock-in averaging technique, peaks at a particular emission rate are detected as a function of temperature. By looking for emissions at different frequencies and monitoring the temperature of the associated peak, an Arrhenius plot allows for the deduction of a trap's activation energy.  By varying the pulse width, it is possible to determine the capture cross section precisely.  

DLTS PEAK IDENTIFICATION:

ACTIVATION ENERGIES FOR VARIOUS IMPURITIES:


 

 

ARRHENIUS PLOT LIBRARY:

 

FEATURES

  • State-of-the-art contamination identification with the highest sensitivity available on the market
  • Complete range of measurement modes, including temperature scan, frequency scan, depth profiling, C-V characterization, capture cross-section measurement, optical injection, conductance transient measurements
  • Controlled by user-friendly GUI
  • Sample quality test by I-V and C-V

  • Full computer control with extensive software support featuring the latest evaluation procedures of physics of deep levels, complete (extensive and expandable) library database for accurate contamination determination

  • Different cryostats with wide temperature ranges are available, depending on the application requirements

 

Product Line

DLS

Interfacing to a broad range of cryostats

Complete range of measurement modes:

  •  Temperature scan
  •  Frequency scan
  •  Depth profiling
  •  C-V characterization
  •  Capture cross section measurement
  •  Optical injection
  •  Conductance transient measurements

Optional digital or analog control of settings to allow real ease of operation

  • Sample quality test by I-V, C-V
  • Full computer control with extensive software support, complete library database for accurate contamination identification

 

 

Products

DLS-1100 Deep Level Transient Spectrometer

DLS-1100 Deep Level Transient Spectrometer provides metrology of the highest sensitivity for characterization and identification of impurities ans defects (known as traps) for the wafermaker market and research institutes.
The new technologies - a low-vibration cryostat with improved signal-to-noise ratio, a more accurate temperature controller and the improved evaluation software - allow for automatic control of the experimental parameters and automatic evaluation of trap concentration, activation energy and capture cross section on semiconductor samples.

Applications and Measurement modes

Electrically active defects’ identification and complete range of measurement modes, including:

  • Sample quality test by I-V, C-V
  • Capacitance transient measurement by using lock-in integrator for
    • temperature scan,
    • frequency scan,
    • depth profiling,
    • capture cross section,
    • MOS interface state density distribution measurements
  • Digitization of the capacitance transient and evaluation for further analysis via Transient recorder
  • Current DLS (I-DLS) option for high conductivity samples

Cryostats

DLS-1100 system can be combined with different cryostats capable of measuring with different temperature ranges:

  • Low vibration cryostat chamber 30K-400K (optionally up to 800K)
  • Closed Cycle He-cryostat from 30K to 325K 
  • Bath-type Liquid Nitrogen cryostat (77K – 450K)
  • Automatic LN2 cryostat with controlled LN2 flow from 80K to 550K or from 80K to 800K

Benefits

  • Highest sensitivity for detection of trace levels of contaminants: down to 5x107 atoms/cm3
  • More accurate temperature measurement (<1 K) with up to 10 sensors
  • Fully automated measurements, capability of capacitance transient digitization and numerical evaluation due to evaluation software improvements

Request Info

DLS-1000 Deep Level Transient Spectrometer

DLS-1000 is an improved, high sensitivity system. It is eight times more sensitive than its predecessor, the DLS-83D.

The DLS-1000 offers a fully automatic measurement mode as well as providing complete interpretation of the measured data, including impurity identification and concentration determination without any need for user interaction.

The deep level transient spectroscopy (DLTS) is the best technique for monitoring and characterizing deep levels caused by intentionally or unintentionally introduced impurities and defects in semiconductor materials and complete devices. It is an extremely versatile method for determining all parameters associated with deep traps including energy level, capture cross section and concentration distribution. It permits identification of the impurities and is capable of detecting contamination concentrations below 2*108 atoms/cm3.

Key Features

  • Highest sensitivity (2*108 atoms/cm3) for detection of trace levels of contamination
  • Interfacing to a broad range of cryostats
  • Wide range of measurement modes:
    • temperature scan
    • frequency scan
    • depth profiling
    • C-V characterization
    • capture cross section measurement
    • optical injection
    • conductance transient measurements
       
  • Controlled by digital and analog settings to allow real ease of operation
  • Sample quality test by I-V, C-V
  • Full computer control with extensive software support, complete library database for accurate contamination identification  

Request Info

Cryostats for Semilab DLS systems

Semilab offers the following Cryostats to use with the DLS systems:

  1. Low vibration cryostat chamber 30K-400K (optionally up to 800K) – equipped with manipulators for easily establishing good electrical contact on small samples and devices and for readjusting the contact needles at low temperatures still under vacuum.
  2. Bath type cryostat: 77K-450K –– heating is computer-controlled – controller built into DLS-1000. Convectional (in LN2 atmosphere)
  3. Automatic LN2 cryostat 80K - 550K (maximum 800K optional). Sample in the vacuum chamber – requires computer-controlled heating and cooling (by LN2 boiling), requires controller  and cryostat control unit.
  4. Automatic He (closed cycle) vacuum cryostat*: 30K - 325K. Controller is commercial LakeShore – controlled by the DLS control software.

*Vacuum cryostats require vacuum pump (not included by default)