A blanket layer of silicon can be added to a silicon substrate by a CVD process to achieve changes in the properties, like resistivity, type and defect density. This CVD process is called epi (or epitaxial) deposition. The thickness monitoring of the epi layer is part of the production process of making the epi wafers. This monitoring is executed on a sample basis, or only to confirm that the epi reactor is set up properly.
Semilab can offer non-contact optical solution for Epi thickness monitoring, depending on infrared reflection techniques.
Fourier Transformed Infrared Spectroscopy (FTIR) based on Michelson Interferometer is a non-contact, non-destructive measurement technique for EPI thickness, dielectric composition, bulk impurities and high dopant concentration monitoring.
It allows industry standard rapid interferogram measurement for epi thickness, reflection spectrum measurement for multilayer analysis and dielectric composition measurements, and optionally transmission measurement for absorption peak analysis.
1. Si EPI Thickness with Interferogram
2. Transition zone thickness acquired from Reflectance measurement using optical modelling
3. BPSG concentration measurement using PLS algorithm
4. Peak analysis in transmission spectra
The system has a strong modular and versatile design to meet the needs of a high reliability, high throughput epi thickness measurement.
The EIR-3000 is a unique automated epi thickness measurement system with infrared spectroscopic reflectometer for high throughput epi thickness measurement. Fully compliant to the relevant SEMI / CE standards. The EIR product line is based on smart, reliable electronics, which improves equipment uptime and decreases maintenance needs.
Applications
Features
EIR-3000 | |
---|---|
Loadport | 1 or 2 loadports, full OHT compatibility |
Sample sizes | 12” |
Substrate materials | Si |
Edge grip | Edge grip robot by default |
FFU | FFU included |
SECS/GEM compatible | Yes |
Options
The EIR-2201 is a unique automated epi thickness measurement system with infrared spectroscopic reflectometer for high throughput epi thickness measurement. Fully compliant to the relevant SEMI / CE standards. The EIR product line is based on smart, reliable electronics, which improves equipment uptime and decreases maintenance needs.
Applications
Features and System Specifications
EIR-2201 | |
---|---|
Loadport | 2 open cassettes |
Sample sizes | 4-5” or 6-8” |
Substrate materials | Si, SiC |
Edge grip | Non-edge grip |
FFU | without FFU |
Options